            PERMIT NBR: 2008030241    JOB DESC: BLDG 12//CBS M/F 2 STY 10-UNIT AFFORDABLE HOUSING     STATUS: COED

            JOB LOCATION: 9063 GERVAIS CIR    FOLIO NUMBER: 0000049660081585

            SUBDIVISION: Heritage Bay Commons / 3838    BLOCK: BLDG 12    LOT: 

            MASTER NBR:       TRS:     TAZ: 191

            COA:  04-6672     FLOOD ZONE: X

            OWNER NAME: LENNAR HOMES LLC      JOB PHONE:    (239)278-1119

            CERT NBR: 20276   DBA: LENNAR HOMES LLC      JOB VALUE: $1,308,000

            CONTACT NAME: JENNIFER     CONTACT PHONE: (239)278-1119

            SETBACKS:  FRONT: 15.00  REAR: 10.00  LEFT:   RIGHT:    SPECIAL: SSB .5 BH/ SEP .5 SBH

            UNIT:    TRACT: NONE     WATER: CC    SEWER: NC

IMPORTANT DATES:

APPLY APPROVE ISSUED CO EXPIRE CANCEL EXT-EXPIRE
3/5/2008 3/17/2008 5/16/2008 11/17/2008 11/12/2008

SUB CONTRACTORS:

Cert NumberSub StatusStart DateEnd DateStatusSub ClassDBA
20064ACTIVE 05/09/2008 CANCEL ME SUNSET AIR, INC.
24321ACTIVE 05/09/2008 INACTIVE EL PREMIER ELECTRIC
14585ACTIVE 05/09/2008 INACTIVE RF AD-LER ROOFING, INC.
15438ACTIVE 05/21/2008 INACTIVE PB SOUTH FLORIDA PLUMBING


SUB PERMITS:

No sub permit data to display.

FEE SCHEDULE:

Fee CodeStatusDescriptionWaiveAmount DueEnter Date
06IMIS POSTEDINSPECTION MISC. FEEN $40.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
06REIN1 POSTEDREINSPECTION 1N $75.0011/13/2008 12:00:00 AM
08APPF POSTEDFIRE PLAN REVIEW APP FEEN $790.003/5/2008 12:00:00 AM
08APPF POSTEDFIRE PLAN REVIEW APP FEEN $-790.003/17/2008 12:00:00 AM
08BACR POSTEDBLDG. PERMIT APP. FEE CREDITN $-1741.70 
08BAPP POSTEDBLDG. PERMIT APPLICATION FEEN $1741.703/5/2008 12:00:00 AM
08BCAI POSTEDBLDG.CODE CERT. SURCHARGEN $77.873/17/2008 12:00:00 AM
08BPNP POSTEDBLDG PERMITS - NAPLESN $6276.463/17/2008 12:00:00 AM
08BREV POSTEDPERMIT REVISIONN $175.008/27/2008 12:00:00 AM
08CPMF POSTEDCOMM PK IMPACT FEE M/FY $8625.003/17/2008 12:00:00 AM
08EMMMF POSTEDEMS IMPACT FEE M/FY $1201.403/17/2008 12:00:00 AM
08FLNN POSTEDFIRE< 1 MILLION-NORTH NAPLESN $968.343/17/2008 12:00:00 AM
08FPRF POSTEDFIRE PLAN REVIEW FEEN $790.003/17/2008 12:00:00 AM
08FPRF POSTEDFIRE PLAN REVIEW FEEN $50.008/22/2008 12:00:00 AM
08GBMF POSTEDGOVT BLDG IMPACT FEE M/FY $4501.803/17/2008 12:00:00 AM
08JLMF POSTEDJAIL IMPACT FEE M/FY $923.083/17/2008 12:00:00 AM
08LBMF POSTEDLIBRARY IMPACT FEE M/FY $4027.903/17/2008 12:00:00 AM
08LWMF POSTEDLAW ENF IMPACT FEE M/FY $1862.003/17/2008 12:00:00 AM
08MFR6 POSTEDDIST 6 ROAD IMPACT FEE-MULTI-FY $78585.203/17/2008 12:00:00 AM
08MFSG POSTEDMICROFILM SURCHARGEN $52.263/17/2008 12:00:00 AM
08NGCC POSTEDGEN. CONTR. CHANGE-NAPLESN $50.009/4/2008 12:00:00 AM
08NNIM POSTEDNORTH NAPLES FIRE IMPACTN $4360.723/17/2008 12:00:00 AM
08RDGS POSTEDBLDG. PERMIT SURCHARGEN $77.873/17/2008 12:00:00 AM
08RPMF POSTEDREG PK IMPACT FEE M/FY $19078.503/17/2008 12:00:00 AM
08SCHI POSTEDSCHOOL BOARD IMPACT FEEY $31396.103/17/2008 12:00:00 AM
11PLNRV POSTEDZONING PLAN REVIEW-PLANNINGN $125.003/5/2008 12:00:00 AM
11PUDM POSTEDPUD MONITORING FEEN $1000.003/17/2008 12:00:00 AM
19APFA POSTEDCOA APP FEEN $100.003/5/2008 12:00:00 AM

INSPECTION HISTORY:

REQClassDescription/RemarksPriorityRequest DateResult CodeResult DateInspector
099 ST NOTICE OF COMMENCEMENT 5/19/08 or 4337 pg 2716 /bjg005/19/200890 05/19/2008BARBGARBROUGH
105  SHEARWALL/FOUND WALL/TILT-UP  07/17/200890 07/17/2008kincaid
107  SHEATHING METAL FASCIA Bottom level floor trusses 07/18/200892 07/18/2008kincaid
107 ST SHEATHING METAL FASCIA No truss eng. packet on site. 2nd fl. roof plywood o.k.007/21/200881 07/21/2008belyea
107  SHEATHING METAL FASCIA Units 6,7,8,9,and 10 07/22/200892 07/22/2008kincaid
107  SHEATHING METAL FASCIA Need R.S. repairs and check eng. sheets marked in red at 108 inspection 07/23/200891 07/23/2008kincaid
108  FRAMING Per Ray 08/18/200875 08/18/2008kincaid
108  FRAMING Front porches and lanais only 08/22/200892 08/22/2008kincaid
108  FRAMING Fire stops missing and top plate penetrations throughout. 09/22/200881 09/22/2008kincaid
108 ST FRAMING 009/23/200890 09/23/2008kincaid
109  INSULATION front & rear porches ok; only 08/27/200892 08/27/2008laterneau
109 ST INSULATION  09/26/200890 09/26/2008rivard
110 ST  006/11/200870 06/11/2008CHANCY_H
111  ROOFING IN PROGRESS Dried in - valley metal, drip edge and wall flashing in place; Roof loaded. 07/25/200891 07/25/2008kincaid
115  FINAL BUILDING R.S. eng. for truss repairs to file. 11/13/200891 11/13/2008kincaid
118 ST  006/11/200890 06/11/2008CHANCY_H
119 ST  006/11/200890 06/11/2008CHANCY_H
122 ST 10 DAY SPOT SURVEY f.f.e = 17.8 /nd006/12/200890 06/09/2008DAY_N
130  TENANT SEP FRAMING  09/26/200890 09/26/2008kincaid
131 ST TENANT SEP DRYWALL done at 108 insp /nd011/13/200891 11/13/2008JAMESKINCAID
132  TENANT SEP INSULATION  09/26/200890 09/26/2008ellis
133  MONOLITHIC SLAB  06/02/200890 06/02/2008kincaid
134  FINAL ROOFING  11/12/200890 11/12/2008kincaid
135 ST FINAL SHUTTERS 11/13/08 SAME DAY FEE $40.00 PER RAY /BJG011/13/200890 11/13/2008JAMESKINCAID
200  PLUMBING ROUGH plumbing ok ; remove rocks 05/22/200881 05/22/2008laterneau
200 PB PLUMBING ROUGH REQUEST ADDED THRU AIRS005/23/200890 05/23/2008laterneau
201  PLUMBING TUB SET per ray 08/07/200875 08/07/2008laterneau
201 PB PLUMBING TUB SET REQUEST ADDED THRU AIRS008/08/200890 08/08/2008laterneau
202  PLUMBING STACK TEST per ray 08/07/200875 08/07/2008laterneau
202 PB PLUMBING STACK TEST REQUEST ADDED THRU AIRS008/08/200890 08/08/2008laterneau
203  SEWER TAP  05/22/200890 05/22/2008laterneau
204 PLBG  011/13/200890 11/13/2008HOOKEREARL
300  MECHANICAL ROUGH A/C per Ray 08/18/200875 08/18/2008rivard
300  MECHANICAL ROUGH A/C studguard all main drainlines and dryer vents, main drainlines where 1" reduces to 3/4 must be connected with pvc fitting, front rt main drainline not connected in wall @ 1st floor 08/21/200881 08/21/2008rivard
300  MECHANICAL ROUGH A/C  08/25/200890 08/25/2008rivard
301  FINAL MECHANICAL A/C  08/18/200875 08/18/2008rivard
301 FINAL MECHANICAL A/C 1602.2 seal around drainline penetrations at drainpan access panel at ahu, 1411.3.1 center ahu's over emergency drainpans, 1601.8 plenums not sealed at ahu's 11/12/200881 11/12/2008rivard
301 ME FINAL MECHANICAL A/C 011/13/200890 11/13/2008rivard
302  MECHANICAL PIPING n/a 11/12/200870 11/12/2008rivard
500 EL ELECTRICAL T POLE 1 meter fpl 06/26/200890 06/26/2008klutsarits
501  ELECTRICAL ROUGH Inspection incomplete. 1. Upstairs bedroom on west side of structure N/M cable under window is required to be protected. 2. All exhaust fans are required to be made up at time of 501 electrical rough. 3. GFCI receptacles are required at mechanical equipment location for maintenace and servicing. 4. Feeder conduits are required to be installed at time of 501 electrical rough. 08/18/200881 08/18/2008ellis
501  ELECTRICAL ROUGH  08/21/200890 08/21/2008ellis
502  FINAL ELECTRICAL Units 1201 thru 1205 only 11/12/200892 11/12/2008davidson
502 EL FINAL ELECTRICAL 011/13/200890 11/13/2008wincer
504  TEMPORARY POWER 10 unit meters and 1 house meter 10/14/200891 10/14/2008ellis
506  UNDERGROUND WIRING what area are you looking for to have inspected 09/10/200892 09/10/2008ellis
506  UNDERGROUND WIRING The area that the underground service lateral's are installed at is an area of the development that according to the site pans is subject to escavating landscaping. I will need a hole dug in the middle of the trench to verify depth of underground installation 09/12/200881 09/12/2008ellis
506  UNDERGROUND WIRING  09/16/200890 09/16/2008ellis
508  TV/TELE ROUGH  08/18/200890 08/18/2008ellis
509  FINAL TV/TELE Units 101 thru 1205 only 11/12/200892 11/12/2008davidson
509 EL FINAL TV/TELE 011/13/200890 11/13/2008wincer
618 ST FINAL FIRE REC'D FAXED FIRE CERT -- STILL NEED ORIGINAL -- NO FEES DUE /ND011/13/200892 11/13/2008DAY_N
618 ST FINAL FIRE rec'd fire cert -- no fees due /nd011/17/200890 11/17/2008DAY_N
800 RW  011/13/200870 11/13/2008MORERAJORGE
801    11/13/200890 11/14/2008MOSS_R
802    11/13/200890 11/14/2008MOSS_R
803    11/13/200890 11/14/2008MOSS_R
810    11/13/200890 11/14/2008MOSS_R
814    11/13/200890 11/14/2008MOSS_R